Reference Guide

To run this subcommand, you must have the Administrator privilege.
NOTE: The special characters “ (double quotation mark), ‘ (backward quotation
mark), & (ampersand), and \ (backward slash) are not supported for this
subcommand.
Synopsis
racadm setchassisname <name>
NOTE: Chassis name is a maximum of 64 nonextended ASCII characters.
Example
racadm setchassisname dellchassis-1
The chassis name was set successfully.
setflexaddr
Description Enables or disables FlexAddress on a particular slot or fabric.
To run this subcommand, you must have the Chassis Configuration Administrator
privilege.
If the fabric type is determined to be InfiniBand, the operation is canceled and the
command returns an error. If the FlexAddress feature is not activated, the command
returns an error.
NOTE: The server must be turned off to change the slot state. All servers must be
turned off to change the fabric state. The MAC/WWN addresses must be managed
locally (not by an external console) to run this command.
Synopsis
racadm setflexaddr -i <slotNum> 0|1
racadm setflexaddr -f <fabricName> 0|1
Input
-i <slotNum> — Enables or disables FlexAddress for the specified slot.
-f <fabricName> — Enables or disables FlexAddress for the specified fabric.
<slotNum>= 1–16
<fabricName>= A, B, C, iDRAC
0 : Disable
1 : Enable
Example
Disable flexaddress for slot 2.
racadm setflexaddr -i 2 0
Enable flexaddress for fabric A.
racadm setflexaddr -f A 1
Disable flexaddress for fabric B.
racadm setflexaddr -f b 0
Disable flexaddress for fabric iDRAC.
racadm setflexaddr -f idrac 0
78