Reference Guide

FanSpeed 6 Fan-6 OK 4829 rpm 2344 14500
FanSpeed 7 Fan-7 OK 4719 rpm 2344 14500
FanSpeed 8 Fan-8 NOT OK 1 rpm 2344 14500
FanSpeed 9 Fan-9 OK 4815 rpm 2344 14500
Temp 1 Ambient_Temp OK 22 celcius N/A 40
<senType> <Num> <sensorName> <status> <health>
PWR 1 PS-1 Online OK
PWR 2 PS-2 Online OK
PWR 3 PS-3 Online OK
PWR 4 PS-4 Slot Empty N/A
PWR 5 PS-5 Failed OK
PWR 6 PS-6 Slot Empty N/A
<senType> <Num> <sensorName> <status>
Cable 1 IO-Cable OK
Cable 2 FPC-Cable OK
getslotname
Description
Displays the name of the slot in the chassis. Optionally, this command can be used to
find if the slot name, host name, or iDRAC DNS name is displayed in the CMC User
Interface or with the getslotname —i <slotNum> | —h command.
NOTE: If the Slot Name, Host Name, and iDRAC DNS Name exceed the character
limit, the names are truncated while displaying for all the slots in the chassis
To use this subcommand, you must have the CMC Login User privilege.
Synopsis
racadm getslotname
racadm getslotname -i <slotNum>
racadm getslotname -h <enabled>
Input
racadm getslotname — Displays the slot name for all 16 slots in the chassis.
-i <slotNum> — Displays the ID of the slot.
Legal values: 1–16
-h <enabled> — Specifies whether to use the slot name, the host name, or the
iDRAC DNS name. The following are the valid options:
0 = Displays slot name.
1 = Displays host name instead of slot name.
2 = Displays the iDRAC DNS name instead of slot name.
60