Reference Guide
Server-16-
B
10 GbE KR Present F8:DB:88:3D:
6F:49
Unknown FlexAddress
Server-16-
C
10 GbE KR Present F8:DB:88:3D:
6F:4D
Unknown FlexAddress
Displays Ethernet and iSCSI MAC/WWN address, Assignment Type, and Partition Status of all LOMs or
mezzanine cards.
racadm getmacaddress -c all
<
Name> <Type> <Presence> <Active WWN/
MAC>
<Partition
Status>
<Assignment
Type>
server-4-
A
IDRAC-
Controller
Present 00:22:19:D2:2
1:F5
N/A Factory
Server-7-
A
10 GbE KR Present 00:90:FA:
51:34:F4
Disabled Factory
10 GbE KR/3 Present 00:90:FA:
51:34:F5
Unknown Factory
Switch-6 10 GbE KR Present
00:00:00:00:0
0:00
N/A Factory
getmodinfo
Description Displays configuration and status information for all modules or a specified module
(server, switch, CMC, fan unit, power supply unit (PSU), KVM, or I2C cable) in the chassis.
A power state of "Primary" denotes Active CMC.
To run this subcommand, you must have the CMC Login User privilege.
NOTE: The Service tag field is blank for modules that do not have service tag.
Synopsis
racadm getmodinfo [-m <module>] [-A]
Input
• -m <module> — Specifies the module whose configuration and status information
you want to view. The default command (no options) displays information about all
major components in the chassis.
<module> may be any of the following values:
– server-<n> where n=1–16
– server-<nx> where n=1–8; x = a, b, c, d
– switch-<n> where n=1–6
– cmc-<n> where n=1–2
– fan-<n> where n=1–9
– ps-<n> where n=1–6
– chassis
– kvm
50