Reference Guide

Switch-4 N/A None Not Present N/A
Switch-5 N/A None Not Present N/A
Switch-6 N/A None Not Present N/A
[Enhanced Cooling Mode]
Enhanced Cooling Mode(ECM) Status = Disabled
getioinfo
Description Displays general information about the I/O modules on the chassis.
To run this subcommand, you must have the CMC Login User privilege.
NOTE: The fabric type may be any supported I/O fabric type, such as Ethernet,
Fibre Channel, and InfiniBand.
Synopsis
racadm getioinfo [-m <module>] [-s]
racadm getioinfo -o
racadm getioinfo -m switch-<n> -o
Input
-m <module> — Specifies the module or device.<module> must be switch — <n>,
where n = 1–6
-s — Displays stack information.
-o — Displays IOA Flex and Fixed module information. The possible values for the
flex module type are:
04x10G Base-T FlexIO Module
14x10G SFP+ FlexIO Module
22x40G QSFP+ FlexIO Module
34xFC FlexIO Module
4No flex module installed
>4Invalid
Example
racadm getioinfo
<IO> <Name> <Type> <Presenc
e>
<POST> <Power> <Role> <SecureMod
e>
<Mode>
switc
h-1
MXL
10/40Gb
E
10 GbE
KR
Present OK ON Master
No
Full
Switch
switc
h-2
PowerEd
ge M
I/O
Aggrega
tor
10 GbE
KR
Present OK ON Standa
lone
No
Standa
lone
42