Reference Guide
Groups Key Attributes
cfgEmailAlert cfgEmailAlertAddress
cfgLDAPRoleGroup cfgLDAPRoleGroupDN
cfgServerInfo cfgServerBmcMacAddress
cfgStandardSchema cfgSSADRoleGroupName
cfgTraps cfgTrapsAlertDestIPAddr
cfgUserAdmin cfgUserAdminUserName
• Displays a list of the available configuration groups on CMC in an alphabetical order.
racadm getconfig -h
• Displays the configuration properties for the user named root.
racadm getconfig -u root
• Displays the user group instance at index 2 with verbose information for the property
values.
racadm getconfig -g cfgUserAdmin -i 2 -v
• Displays an entire group of serial configuration.
racadm getconfig -g cfgSerial
• Displays a single object from a particular group.
racadm getconfig -g cfgSerial -o cfgSerialBaudRate
• Displays an indexed group.
racadm getconfig -g cfgUserAdmin -o cfgUserAdminUserName -i 2
• Displays information about the session information for a particular server.
racadm getconfig -g cfgSessionManagement -m server-1
• Displays information about the WEB/SSH/Telnet information for a particular server.
racadm getconfig -g cfgRacTuning -m server-1
• Displays information about the remote Syslog for a particular server.
racadm getconfig -g cfgRemoteHosts -m server-1
• Displays the current Enhanced Cooling Mode property configuration.
racadm getconfig –g cfgThermal
getdcinfo
Description Displays general I/O module and daughter card configuration information. Only the
CMC controls daughter cards.
To run this subcommand, you must have the CMC Login User privilege.
NOTE: Fabric verification for server DCs is performed only when the chassis is
turned on. When the chassis is on standby power, iDRACs on the server modules
remain turned off and thus are unable to report the server's DC fabric type. The DC
fabric type may not be reported in the CMC user interface until iDRAC on the server
is turned on.
Synopsis
• racadm getdcinfo
• racadm getdcinfo [-n]
Input -n — Displays the model names for the daughter cards in servers.
36