Reference Guide
Module ID = 10
Severity = Critical
Message = General failure after video.
Module ID = ps-6
Severity = Critical
Message = The power input for power supply 6 is lost.
• To display critical error messages for server–1.
racadm getactiveerrors –s critical –m server-1
Module ID = 1
Severity = Critical
Message = The storage battery has failed.
• The error message displayed for invalid syntax.
racadm getactiveerrors –z cmc-1
ERROR: The syntax of the command specified is not correct.
• The error message displayed for invalid parameter.
racadm getactiveerrors –m server-80
ERROR: The syntax of the command specified is not correct.
• To display entire information log.
racadm getactiveerrors -s info
Module ID = 1
Severity = Critical
Message = A fabric mismatch deteceted for mezzanine card B1.
Module ID = ps-1
Severity = Critical
Message = The power input for power supply 1 is lost.
Module ID = ps-3
Severity = Critical
Message = The power input for power supply 3 is lost.
Module ID = cmc-1
Severity = NonCritical
Message = A firmware or software incompatibilty detected
between system BIOS in slot 4 and CMC.
• Display specific module log:
racadm getactiveerrors -m server-1
getarraycfg
Description
To display the storage array properties and configuration status, run this command.
Synopsis
getarraycfg -m <module> [-s]
Input
• -m — The valid value for —m <module> is server–<n>, where n = 1 to 7 and 9 to 15.
• -s — Query for current storage configuration process status.
Output Array configured properties for:
• Member Name
• Member IP
• Group Name
33