Reference Guide
-s <severity> — Specifies the severity type message displayed. The command
racadm getactiveerrors displays the selected type of messages for all the modules.
When used with
-m option, only selected message type for that module is displayed.
The values for -s <severity> are:
• critical
• warning
• info
-m <module> — Specifies the module for which the messages such as critical,
noncritical (warning), and informational are displayed. The command racadm
getactiveerrors displays critical, noncritical (warning), and informational messages
for the selected module. When used with
-s option, only selected message type for the
module is displayed. The values for -m <module> are:
• server-<n> — where n=1–16
• server-<nx> — where n=1–8; x = a, b, c, d (lower case)
• switch-<n> — where n=1–6
• cmc-<n> — where n=1, 2
• fan-<n> — where n=1–9
• ps-<n> — where n=1–6
• chassis
• kvm
• lcd
NOTE: A few of the informational messages are applicable for more than one
module. To avoid repetition of the same message for different modules, only one
such informational message is displayed for the default command racadm
getactiveerrors. When an -m option is used on another server or switch, the
informational message is displayed, if applicable.
After you run this command, the full-height, half-height, and the quarter-height
servers and switches are automatically checked for informational messages (in the
same order as mentioned here).
Examples
• To display the entire log (Critical, Warning and Informational messages) for all
modules.
racadm getactiveerrors
Module ID = 1
Severity = Critical
Message = The storage battery has failed.
Module ID = 10
Severity = Critical
Message = General failure after video.
Module ID = ps-6
Severity = Critical
Message = The power input for power supply 6 is lost.
• To display Critical error messages for all the components.
racadm getactiveerrors –s critical
Module ID = 1
Severity = Critical
Message = The storage battery has failed.
32