Reference Guide

fwupdate
Description
Allows you to update the firmware on the KVM, active CMC, standby CMC, iDRAC or an
IOM infrastructure device. You can:
Check the firmware update process status.
Update CMC from FTP or TFTP server by providing an IP address and optional path.
Update CMC from the local file system using Remote RACADM.
There can only be a single update operation in progress at any time. In addition, the
fwupdate subcommand may only update one or more devices of a single kind at a
time.
NOTE: CMC firmware update is supported only for the firmware versions 3.10, 3.20,
3.21, 4.0, 4.10, 4.11, 4.30, 4.31, 4.45, and 4.5. For any version other than these, first
update to any of these versions, and then update to the required version.
To use this subcommand, you must have the Chassis Configuration Administrator
privilege.
NOTE: The fwupdate command is not supported for iDRAC7 or later. Use the CMC
GUI to perform the operation.
NOTE:
Running the fwupdate subcommand to update the firmware on the active CMC
resets itself and all the network connections are dropped. During update of all
other modules, including the standby CMC, the active CMC continues to run
normally without resetting.
In a chassis supported by DC PSUs, an error message is displayed if you attempt
to update the firmware with a version without DC PSU support.
The fwupdate subcommand generates an error when used on the extension
slot of a multi-slot server.
While Lifecycle Controller is running for racadam commands, you cannot
perform other operations which needs Lifecycle Controller Partition. If the
Lifecycle Controller Partition is unreleased (because of improper closure of
racadm command in the partition), then you must wait 20-35 minutes to clear
the Lifecycle Controller Partition
Signed CMC Firmware Image
For 13th generation and later, CMC firmware includes a signature which is verified by
CMC before update to ensure the authenticity of the uploaded firmware. The
firmware update process is successful only if the firmware image is authenticated by
CMC to be a valid image from the service provider and has not been altered. The
firmware update process is stopped if CMC cannot verify the signature of the
uploaded firmware image.
Upload firmware image from TFTP server and start firmware update.
Synopsis
For SSH or Telnet or Serial:
racadm fwupdate -g -u -a <tftp_server_ip_address_or_FQDN> -d
<path> [-m <module>]
racadm fwupdate -f <ftp_server_ip_address_or_FQDN> <username>
<password> -d <path> [-m <module>]
racadm fwupdate -u -m iominf-<n>
racadm fwupdate -s [-m <module>]
racadm fwupdate -c [-m <module>]
27