Reference Guide

connect
Description Connects to the switch or blade server serial console.
NOTE: This subcommand is only supported on the firmware interface(s).
Synopsis
racadm connect [-b] —m <module>
Input
-b — Connects to the switch or console using the binary mode. -b is an optional; a
server or a switch must be present.
NOTE: If you use the -b option, reset the CMC to end the connect operation.
-m <module> — Must be one of the following values:
server –<n> — where n=1–16
server –<nx> — where n=1–8; x = a, b, c, d (lower case)
switch –<n> — where n = 1 to 6 or <a1 | a2 | b1 | b2 | c1 | c2>
Example
Connect to I/O Module 1 serial console:
racadm connect -m switch-1
Connect to server 1 serial console:
racadm connect -m server-1
deploy
Description Deploys blade server or IOM by specifying the required properties.
To use this subcommand, you must have the Server Administrator privilege.
NOTE: Use setniccfg to configure static IP address, subnet mask, and gateway, and
DHCP, speed and duplex properties.
Synopsis
racadm deploy -m server-<n> -u root -p <password> -s
<ipaddress> <subnet> <gateway> -b <device> -o no | yes
racadm deploy -m server-<n> -u root -p <password>-s -6
<ipv6Address> <prefixlen> <gateway> -b <device> -o no | yes
where <prefixlen> must be a number between 0 and 128.
racadm deploy -m server-<n> -u root -p <password> -d [-6]
racadm deploy -m switch-<n> -u root -p <password>
racadm deploy -m switch-<n> -v SNMPv2 <snmpCommunityString> ro
racadm deploy -a [server/switch] -u root -p <password>
racadm deploy -q [-n <numofblades>]
Input
—b <device> — Specifies the first boot device must be used with -o. Use with-m
<module> to specify for an individual server, or with an -a for all servers.
Legal values are: None, PXE, HDD, CD-DVD, vFDD, vCD-DVD, iSCSI, SD, FDD, RFS.
-o no/yes — Indicates if the server must start from the device once. Use this
option with -b option.