Reference Guide
cfgChassisAllow110VACOperation=0
cfgChassisMaxPowerConservationMode=0
cfgChassisPerformanceOverRedundancy=1
# cfgSystemEnergyConsumptionClear = ****(Write-Only)
cfgChassisServerBasedPowerMgmtMode=0
• racadm config -g cfgChassisPower ‑o cfgChassisPowerClear 1
Clears cfgChassisMinPower and cfgChassisPeakPower.
cfgThermal
This group displays and configures the thermal settings. Use this object with the config or getconfig
subcommands.
To set the configurations, you must have the Chassis Configuration Administrator privileges.
cfgThermalMFSPercent (Read or Write)
Description
Configures the minimum fan speed in percent.
Legal Values
0 to 100
Default
0
cfgThermalEnhancedCoolingMode (Read or Write)
Description
Configures the enhanced cooling mode.
Legal Values
• 1 — Enabled
• 0 — Disabled
Default 0 — Disabled
cfgKVMInfo
This group is used to display information for and configure the iKVM.
Use this object with the config or getconfig subcommands.
To use this object property, you must have Chassis Configuration Administrator privilege.
cfgKVMAccessToCMCEnable (Read or Write)
Description
Enables or disables the Dell CMC Console access on the iKVM.
Legal Values
• 1 (Enable)
• 0 (Disable)
Default
None
144