Reference Guide
cfgChassisRedundancyPolicy (Read or Write)
Description
Sets the redundancy policy of the chassis.
Legal Values
• 0 — No redundancy
• 1 — Grid redundancy
• 2 — Power supply redundancy
Default
0 — No redundancy
cfgChassisDynamicPSUEngagementEnable (Read or Write)
Description
Enables or disables dynamic engagement.
Legal Values
• 0 — Disabled
• 1 — Enabled
Default 0
cfgChassisAllow110VACOperation (Read or Write)
Description Enables or disables normal chassis power allocations when any PSU is connected to
110V AC service. If disabled and 110V power supplies are detected, all subsequent server
power allocation requests are denied. In this mode more servers cannot be powered on,
regardless of server priority.
Legal Values
• 0 — Disabled
• 1 — Enabled
Default
0
cfgChassisAllow110VACOperationTimestamp (Read Only)
Description The timestamp recorded when Allow110V setting from power management is enabled.
Legal Values
Default 0
cfgChassisMaxPowerConservationMode (Read or Write)
Description
Enables or disables maximum power conservation mode. When enabled, all servers are
immediately reduced to their minimum power levels, and all subsequent server power
allocation requests are denied. In this mode, performance of powered on servers may
be degraded and more servers cannot be powered on, regardless of server priority.
Legal Values
• 0 — Disabled
• 1 — Enabled
140