Reference Guide

cfgRacTuneTimezoneOffset (Read Only)
Description
This object property is read only. Specifies the difference in number of seconds, from
the UTC/GMT. This value is negative if the current time zone is west of Greenwich.
Legal Values
None
Default
0
Example
racadm getconfig -g cfgRacTuning
cfgRacTuneRemoteRacadmEnable=1
cfgRacTuneWebserverEnable=1
cfgRacTuneHttpPort=80
cfgRacTuneHttpsPort=443
cfgRacTuneTelnetPort=23
cfgRacTuneSshPort=22
cfgRacTuneIpRangeEnable=0
cfgRacTuneIpRangeAddr=192.168.1.1
cfgRacTuneIpRangeMask=255.255.255.0
# cfgRacTuneTimezoneOffset=-18000
# cfgRacTuneDaylightOffset=3600
cfgRacTuneWebserverEnable (Read or Write)
Description
Enables or disables the web server. If this property is disabled then it is not accessible
using client web browsers. This property has no effect on the Telnet/SSH or racadm
interfaces.
Legal Values
1 (TRUE)
0 (FALSE)
Default
1
cfgServerInfo
This group allows you to display and configure a server in the chassis.
Use this object with the config or getconfig subcommands.
To use this object property, you must have the Chassis Configuration Administrator privilege.
NOTE: You can configure a setting does not have the hash sign (#) prefixed in the output. To
modify a configurable object, use the —o option
The following sections provide information about the objects in the cfgServerInfo.
120