Users Guide

Severity Message Cause
Critical A failure is detected on I/O module
<number>.
The I/O module has a fault. The same error can
also happen if the I/O module is thermal-
tripped.
Table 50. iKVM Status Screen
Severity Message Cause
Warning Console is not available for Local KVM. Minor failure, such as corrupted firmware.
Critical Local KVM can not detect any hosts. USB host enumeration failure.
Critical OSCAR, on screen display is not
functional for the Local KVM.
OSCAR failure.
Non-
Recoverable
Local KVM is not functional, and is
powered off.
Serial RIP failure or USB host chip failure.
Table 51. PSU Status Screens
Severity Message Cause
Critical Power supply <number> failed. The PSU has failed.
Critical The power input for power supply
<number> is lost.
Loss of AC power or AC cord unplugged.
Warning Power supply <number> is operating at 110
volts, and could cause a circuit breaker
fault.
Power supply is plug into a 110 volt source.
Table 52. Server Status Screen
Severity Message Cause
Warning The system board ambient temperature
is less than the lower warning threshold.
Server temperature is getting cool.
Critical The system board ambient temperature
is less than the lower critical threshold.
Server temperature is getting cold.
Warning The system board ambient temperature
is greater than the upper warning
threshold.
Server temperature is getting warm.
Critical The system board ambient temperature
is greater than the upper critical
threshold.
Server temperature is getting too hot.
Critical The system board Current Latch current
is outside of the allowable range
Current crossed a failing threshold.
Critical The system board battery failed. CMOS battery is not present or has no
voltage.
264