Users Guide

Configuring Management VLAN on IOMs Using Web Interface
You can manage the IO Aggregator in-band through a VLAN. This VLAN must be deployed prior to use.
CMC allows in-band management VLAN deployment. The switch’s in-band management VLAN requires
the following basic configuration of settings to be applied:
Enable
VLAN ID
Priority
NOTE:
Configuring the management VLAN on the Vlan Settings page requires Chassis Configuration privileges.
This privilege is also required for IOM VLAN configuration, in addition to the Administrator privileges to
the specific fabric A, B, or C.
To configure Management VLAN for IOMs using the CMC Web interface:
1. In the system tree, go to Chassis Overview and click NetworkVLAN.
The VLAN Tag Settings page is displayed.
2. In the I/O Modules section, enable VLAN for the IOMs, set the priority and enter the ID. For more
information about the fields, see the CMC Online Help.
3. Click Apply to save the settings.
Configuring Management VLAN on IOMs Using RACADM
To configure management VLAN on IOMs using RACADM, use the racadm setniccfg –m switch-n
-v command.
Specify the VLAN ID and priority of a particular IOM with the following command:
racadm setniccfg -m switch -<n> -v <VLAN id> <VLAN priority>
The valid values for <n> are 1 – 6.
The valid values for <VLAN> are 1 – 4000 and 4021 – 4094. Default is 1.
The valid values for <VLAN priority> are 0 – 7. Default is 0.
For example:
racadm setniccfg -m switch -1 -v 1 7
For example:
To remove an IOM VLAN, disable the VLAN capabilities of the specified IOM's network:
racadm setniccfg -m switch-<n> -v
The valid values for <n> are 1 – 6.
For example:
racadm setniccfg -m switch-1 -v
199