Users Guide

Table 32. : Mapping I/O Modules to Switches
I/O Module Label Switch
A1 switch-a1 or switch- 1
A2 switch-a2 or switch-2
B1 switch-b1 or switch-3
B2 switch-b2 or switch-4
C1 switch-c1 or switch-5
C2 switch-c2 or switch-6
NOTE: There can only be one IOM connection per chassis at a time.
NOTE: You cannot connect to pass-throughs from the serial console.
To connect to a managed server serial console, use the command connect server-<n><x>, where n
is 1-8 and x is a,b, c, or d. You can also use the racadm connect server-n command. When you
connect to a server using the
-b option, binary communication is assumed and the escape character is
disabled. If the iDRAC is not available, you see a No route to host error message.
The connect server-n command enables the user to access the server's serial port. After this
connection is established, the user can view the server's console redirection through CMC's serial port
that includes both the BIOS serial console and the operating system serial console.
NOTE: To view the BIOS boot screens, serial redirection has to be enabled in the servers’ BIOS
Setup. Also, you must set the terminal emulator window to 80x25. Otherwise, the screen is garbled.
NOTE: Not all keys work in the BIOS setup screens, so provide appropriate escape sequences for
CTRL+ALT+DEL, and other escape sequences. The initial redirection screen displays the necessary
escape sequences.
Related Links
Configuring the Managed Server BIOS for Serial Console Redirection
Configuring Windows for Serial Console Redirection
Configuring Linux for Server Serial Console Redirection During Boot
Configuring Linux for Server Serial Console Redirection After Boot
Configuring the Managed Server BIOS for Serial Console Redirection
It is necessary to connect to the managed server using the iKVM (see Managing Servers With iKVM ) or
establish a Remote Console session from the iDRAC Web interface (see the iDRAC User’s Guide on
dell.com/support/manuals).
Serial communication in the BIOS is OFF by default. To redirect host text console data to Serial over LAN,
you must enable console redirection through COM1. To change the BIOS setting:
1. Boot the managed server.
2. Press <F2> to enter the BIOS setup utility during POST.
3. Scroll down to Serial Communication and press <Enter> . In the pop-up dialog box, the serial
communication list displays these options:
Off
172