Users Guide

1
Overview
The Dell Chassis Management Controller (CMC) for Dell PowerEdge M1000e chassis is a systems
management hardware and software solution for managing multiple Dell server chassis. It is a hot-
pluggable card that is installed at the back of Dell PowerEdge M1000e chassis. The CMC has its own
microprocessor and memory and is powered by the modular chassis into which it is plugged.
CMC enables an IT administrator to:
View inventory
Perform configuration and monitoring tasks
Remotely turn on or off servers
Enable alerts for events on servers and components in the M1000e chassis
You can configure the M1000e chassis either with a single CMC, or with redundant CMCs. In redundant
CMC configurations, if the primary CMC loses communication with the M1000e chassis or the
management network, the standby CMC takes over chassis management.
The CMC provides multiple systems management functions for servers. Power and thermal management
are the primary functions of CMC.
Enclosure-level real-time automatic power and thermal management.
CMC monitors system power requirements and supports the optional Dynamic Power Supply
Engagement mode. This mode enables CMC to improve power efficiency by setting the power
supplies in standby based on the load and redundancy requirements.
CMC reports real-time power consumption, which includes logging high and low points with a
time stamp.
CMC supports setting an optional enclosure Maximum Power Limit, which either alerts or takes
actions, such as throttling server modules and/or preventing the power up of new blades to keep
the enclosure under the defined maximum power limit.
CMC monitors and automatically controls cooling of fans based on actual ambient and internal
temperature measurements.
CMC provides comprehensive enclosure inventory and status or error reporting.
CMC provides a mechanism for centralized configuration of :
The network and security settings of M1000e enclosure.
Power redundancy and power ceiling settings.
I/O switches and iDRAC network settings.
First boot device on the servers.
I/O fabric consistency checks between the I/O modules and servers. CMC also disables
components, if necessary, to protect the system hardware.
User access security.
You can configure CMC to send email alerts or SNMP trap alerts for warnings or errors related to
temperature, hardware misconfiguration, power outage, and fan speed.