Reference Guide
• Display Service tag of all the components in the chassis
racadm getsvctag
getsysinfo
Description
Displays information related to CMC, managed system, and watchdog conguration.
Synopsis
racadm getsysinfo [-d] [-A] [-c] [-4] [-6]
Input
• —4 — Displays IPv4 settings
• —6 — Displays IPv6 settings
• —c — Displays common settings
• —d — Displays CMC information
• —A — Eliminates the printing of headers or labels
Output
racadm getsysinfo
CMC Information:
CMC Date/Time = Wed Sep 17 2014 23:13
Primary CMC Location = CMC-1
Primary CMC Version = 5.00
Standby CMC Version = 5.00
Last Firmware Updated = Tue Sep 16 2014 22:11
Hardware Version = A09
CMC Network Information:
NIC Enabled = 1
MAC Address = 78:2B:CB:46:5C:8A
Register DNS CMC Name = 1
DNS CMC Name = cmc-effort
Current DNS Domain = cmc.com
VLAN ID = 1
VLAN Priority = 0
VLAN Enabled = 0
CMC IPv4 Information:
IPv4 Enabled = 1
Current IP Address = 192.168.0
Current IP Gateway = 192.168.0
Current IP Netmask = 255.255.255.0
DHCP Enabled = 1
Current DNS Server 1 = 0.0.0.0
Current DNS Server 2 = 0.0.0.0
DNS Servers from DHCP = 0
CMC IPv6 Information:
IPv6 Enabled = 0
Autoconfiguration Enabled = 0
Link Local Address = ::
Current IPv6 Address 1 = ::
Current IPv6 Gateway = ::
Current IPv6 DNS Server 1 = ::
Current IPv6 DNS Server 2 = ::
DNS Servers from DHCPv6 = 0
Chassis Information:
System Model = PowerEdge M1000e
System AssetTag = 12345678901234567890123456781234456771234567890asvcdefrtghyhytg
Service Tag = JGB6B2S
Chassis Name = CMC-JGB6B2S
Chassis Location = 3rdflor
54