Reference Guide
getled
Description Displays the LED settings on a module: blinking, not blinking, or unknown (for empty slots).
To run this subcommand, you must have the Login User privilege.
Synopsis
racadm getled -m <module>
Input
—m <module> can be one of the following:
• server-<n> where n=1–16
• server-<nx> where n=1–8; x=a, b, c, d (lower case)
• switch-<n> where n=1–6
• chassis
• cmc-active
Output
• LED is blinking
• LED is not-blinking
Example
• racadm getled -m server-10
<module> <LED state>
server-10 Blinking
• racadm getled -m chassis
<module> <LED state>
server-10 Not blinking
• racadm getled -m server-1
<module> <LED state>
server-1 ON
• racadm getled -m server-9
<module> <LED state>
server-9 Extension(1)
getmacaddress
Description
Displays the MAC/WWN addresses and fabric ID decoder for all modules or for a specied module.
The decoder values indicate the protocols of the netowrk cards:
• 0 — Unsupported
• 1 — ISCSI
• 2 — FCoE-FIP
• 3 — iSCSI/FCoE-FIP
To use this subcommand, you must have the CMC Login User privilege.
Synopsis
• racadm getmacaddress
• racadm getmacaddress -m chassis
• racadm getmacaddress -m switch-<n>
• racadm getmacaddress [-m <module> [-x]] [-t iscsi]
• racadm getmacaddress [-a]
•
racadm getmacaddress -c IO-Identity
38