Reference Guide
15 SLOT-15 PowerEdge M630 ON Present 38
16 SLOT-16 N/A N/A Present N/A
Switch Module Fan Request Table
<IO> <Name> <Type> <Presence> <Fan Request%>
Switch-1 PowerEdge M I/O
Aggregator
10 GbE KR Present 30
Switch-2 PowerEdge M I/O
Aggregator
10 GbE KR Present 30
Switch-3 MXL 10/40GbE 10 GbE KR Present 30
Switch-4 N/A None Not Present N/A
Switch-5 N/A None Not Present N/A
Switch-6 N/A None Not Present N/A
[Enhanced Cooling Mode]
Enhanced Cooling Mode(ECM) Status = Disabled
getioinfo
Description
Displays general information about the I/O modules on the chassis.
To run this subcommand, you must have the CMC Login User privilege.
NOTE: The fabric type may be any supported I/O fabric type, such as Ethernet, Fibre Channel, and
InniBand.
Synopsis
racadm getioinfo [-m <module>] [-s]
Input
• -m <module> — Species the module or device.<module> must be switch — <n>, where n = 1–6
• -s — Displays stack information.
Example
• racadm getioinfo
<IO> <Name> <Type> <Presence> <POST> <Power> <Role>
switch-1 Dell
Ethernet
Passthrough
Gigabit
Ethernet
Present OK ON Master
switch-2 N/A None Not Present N/A N/A N/A
switch-3 Brocade
4424
Fibre
Channel 4
Present OK ON Master
switch-4 N/A None Not Present N/A N/A N/A
switch-5 N/A None Not Present N/A N/A N/A
36