Reference Guide
Severity = Critical
Message = The power input for power supply 1 is lost.
Module ID = ps-3
Severity = Critical
Message = The power input for power supply 3 is lost.
Module ID = cmc-1
Severity = NonCritical
Message = A firmware or software incompatibilty detected between system
BIOS in slot 4 and CMC.
• Display specic module log:
racadm getactiveerrors -m server-1
getarraycfg
Description
To display the storage array properties and conguration status, run this command.
Synopsis
getarraycfg -m <module> [-s]
Input
• -m — The valid value for —m <module> is server–<n>, where n = 1 to 7 and 9 to 15.
• -s — Query for current storage conguration process status.
Output Array congured properties for:
• Member Name
• Member IP
• Group Name
• Group IP
• Fabric Selection
<module> conguration completed successfully.
Example
• Get the congured storage array properties from server–3.
racadm getarraycfg -m server-3
• Query for current storage conguration process status on server–3.
racadm getarraycfg -m server-3 -s
getassettag
Description
Displays the asset tag for the chassis.
To run this subcommand, you must have the CMC Login User privilege.
Synopsis
racadm getassettag [-m <module>]
Input -m <module> — Species the module whose asset tag you want to view.
Legal value: chassis
Example
• Display asset tag for chassis
racadm getassettag -m chassis
• racadm getassettag
chassis 78373839–33
29