Reference Guide
• -s <ipaddress> <subnet> <gateway> — Sets the IP address, subnet mask, and gateway for the
specied server.
– ipaddress — A string representing a valid IP address. For example, 192.168.0.20.
– subnet — A string representing a valid subnet mask. For example, 255.255.255.0.
– gateway — A string representing a valid gateway address. For example, 192.168.0.1.
• -d — Enables DHCP for the specied server.
The -s and -d options cannot be used together in the same command.
• -6 — Enables IPv6 auto conguration (when used with -d). Sets static IPv6 addresses (when used with -
s).
• -v SNMPv2 <snmpCommunityString> ro — Species the SNMP community string for switches.
Valid community strings are 1–20 characters in length, with valid ASCII characters in the range [32–125]
(decimal). Protocol version set to SNMPv2. Permission on community string is read-only.
• -q — Displays or modies the quick deploy parameters.
• -n <numofblades> — Species the number of reserved IP addresses for quick deploy. The allowed
values are: 8, 16, and 32.
NOTE: The -q option must be specied with the -n option.
Output None
Example
• Set root password, congure static IPV4 address, set rst boot device to HDD, and enable boot once for
server-1.
racadm deploy -m server-1 -u root -p <password> -s 192.168.0.20
255.255.255.0 192.168.0.1 -b HDD -o yes
• Set root password, congure static IPV6 address, set rst boot device to HDD, and enable boot once for
server-1.
racadm deploy -m server-1 -u root -p <password> -s -6 1 2001:DB8::2 64
2001:DB8::1 -b HDD -o yes
• Set root password and enable DHCP for server-3.
racadm deploy -m server-3 -u root -p <passpwrd> -d
• Set user name and password for switch-2.
racadm deploy -m switch-2 -u <username> -p <password>
• Set SNMP community string for switch-2.
racadm deploy -m switch-2 -v SNMPv2 DemoCommunityString ro
• Set root password to Calvin for all servers.
racadm deploy -a -u root -p calvin
• Set user name and password for all switches.
racadm deploy -a switch -u <username> -p <password>
• View the quick deploy parameters.
racadm deploy -q
• Modify the number of reserved IP addresses for quick deploy.
racadm deploy -q -n 8
feature
Description
Displays all active chassis features. The information displayed includes feature name, date activated and the
serial number of the SD card used to activate the feature.
Dell Feature Cards may contain more than a feature. After any feature included on a Dell Feature Card is
activated on a chassis, any other features that may be included on that Dell Feature Card cannot be activated
on a dierent chassis.
NOTE: To use this subcommand to deactivate FlexAddress, you must have the Chassis Conguration
Administrator privilege. A user with login privileges can view status only.
22