Reference Guide

power, both for redundancy, as well as full performance, then some servers may not grant sucient power for
full performance. In order to maintain redundancy, It may not be powered on.
Legal Values
0 — Disabled
1 — Enabled
Default 1
cfgChassisInMaxPowerCapacity (Read Only)
Description
Indicates the total chassis power budget (in watts) available for chassis operation.
Legal Values
None
Default
None
cfgChassisInRedundancyReserve (Read Only)
Description
Indicates the amount of redundant power (in watts) in reserve that can be utilized in the event if an AC grid or
PSU is unsuccessful. This value is0 if the Redundancy Policy is set to 0 (no redundancy).
Legal Values
0 (disabled)
1 (enabled)
Default
None
cfgChassisInPowerServerAllocation (Read Only)
Description
Indicates (in watts) the cumulative power allocated to servers. There is no default as this parameter is specic
to the particular customer conguration.
Legal Values
None
Default
None
cfgChassisInfrastructureInPowerAllocation (Read Only)
Description
Indicates the estimated cumulative DC output power consumption (in watts), determined from a eld
replaceable unit (FRU) on the hardware modules in the chassis.
Legal Values
None
Default
None
cfgChassisTotalInPowerAvailable (Read Only)
Description
Indicates the amount of power (in watts) available for use by the chassis.
Legal Values
None
Default
None
122