Reference Guide
Default
43221 BTU/hr
cfgChassisPowerCapFBTU (Read or Write)
Description
Indicates the maximum power consumption limit (in BTU/hr) for the entire chassis. Use
cfgChassisCapFBTU when power consumption changes regardless of whether server throttling is required.
The command generates an error if the value for this setting is lower than the minimum power required for the
chassis conguration.
Legal Values
9264–56931 BTU/hr
Default
56931 BTU/hr
cfgChassisPowerCapPercent (Read or Write)
Description
Indicates the power consumption limit as a percentage. The percentage is computed mathematically as the
minimum power + (percent * (maximum power — minimum power)). The command generates an error if
server throttling is necessary to achieve the power goal based on the value for this setting.
Legal Values
16–100
NOTE: If the specied percent is lower than the minimum value, the CMC sets the value to the
minimum value.
Default
100
cfgChassisPowerCapFPercent (Read or Write)
Description
Indicates the power consumption limit as a percentage. The percentage is computed mathematically as the
minimum power + (percent * (maximum power — minimum power)). Use
cfgChassisPowerCapFPercent when power consumption is changes regardless of whether server
throttling is required.
Legal Values
16–100
NOTE: If the specied percent is lower than the minimum value, the CMC sets the value to the
minimum value.
Default
100
cfgChassisRedundancyPolicy (Read or Write)
Description
Sets the redundancy policy of the chassis.
Legal Values
• 0 — No redundancy
• 1 — Grid redundancy
• 2 — Power supply redundancy
Default
0 — No redundancy