Owner's Manual

Additional WSMAN support for OpenManage Power Center.
RACADM support to query active errors.
Default key size for Certificate Signing Requests changed from 1024 to 2048.
Fixes
Resolves an issue with improperly matching sequence numbers of IPMI commands and responses
with PS M4110.
Fixes a security issue with Chassis Group Management.
Fixes an issue with applying all settings profiles.
Important Notes
While using Remote RACADM client with CMC 4.45 version, make sure that Remote RACADM
client version 7.3.0 is installed.
While using the command "racadm config -f" with CMC 3.21 version of firmware, make sure that
Remote RACADM client version 6.3.0 or later is installed.
CMC with firmware version earlier than 3.21, make sure that the Remote RACADM client version
earlier than 6.3.0 is installed.
Known Issues
Issue 1:
Description
Versions 6.0 and 7.0 of Mozilla Firefox Web Browser do not support IPv6 addresses.
Resolution
You must use URLs that contain a registered hostname when accessing a CMC or iDRAC Server that has
an IPv6 address. If the CMC or iDRAC Server also has an IPv4 address, then that is supported.
Versions/Systems Affected
CMC version 2.1 or greater.
Limitations
Issue 1:
Description
The remote racadm testfeature command (racadm -r <IP Address> testfeature..) does not support the -d
(debug) option.
Resolution
None
Versions/Systems Affected
All CMC versions including CMC 4.45.