Reference Guide
To use this subcommand with the get and test option, you must have Administrator
privilege.
This subcommand is applicable only for iDRAC.
Synopsis
racadm eventfilters <eventfilters command type>
racadm eventfilters get -c <alert descriptor>
racadm eventfilters set -c <alert descriptor>-a <action>-n
<notifications>
racadm eventfilters set -c <alert descriptor>-a <action>-r
<recurrence>
racadm eventfilters test -i <Message ID to test>
NOTE: The general format of an alert descriptor:
idrac.alert.category.[subcategory].[severity]
, where, category is mandatory, but subcategory and severity are optional. A
severity cannot precede a subcategory.
Valid Category values are:
• All
• System
• Storage
• Updates
• Audit
• Config
• Worknotes
Valid Severity values are:
• Critical
• Warning
• Info
Valid examples of alert descriptors are:
• idrac.alert.all
• idrac.alert.audit
• idrac.alert.audit.lic
• idrac.alert.audit.warning
• idrac.alert.audit.lic.critical
Input
• get — Displays the list of eventfilter settings.
• set — Configures the actions and notifications for a given eventfilter
configuration.
• -i — Message ID for which the simulation is needed.
• -c — Alert descriptor of the specific event filter.
• -a — The action that must be invoked when the event occurs. Valid values are
none, powercycle, poweroff, or systemreset.
• -n — The notification to be sent when the event occurs. Valid values are all,
snmp, ipmi, lcd, email, or none. You can append multiple notifications separated
by a comma. You cannot enter the values all or none with other notifications.
53