Reference Guide
Write Privilege Configure iDRAC
License Required iDRAC7 Express or iDRAC7 Enterprise
Dependency None
System.Power.Max.Amps.TimeStamp (Read Only)
Description Specifies the timestamp recorded for the Peak Power Consumption since
this value was last cleared.
Legal Values String up to 254 ASCII characters.
Write Privilege Configure iDRAC
License Required iDRAC7 Express or iDRAC7 Enterprise
Dependency None
System.Power.Max.Headroom (Read Only)
Description Displays the difference between the available power and the peak
power consumption.
NOTE: This object is not applicable on iDRAC on Modular
servers.
Legal Values Values from 1 - 65535
Write Privilege Configure iDRAC
License Required iDRAC7 Express or iDRAC7 Enterprise
Dependency None
System.Power.Max.LastDay (Read Only)
Description Displays the maximum power value during the last day.
Legal Values Values from 1 - 65535
Write Privilege Configure iDRAC
License Required iDRAC7 Express or iDRAC7 Enterprise
Dependency None
System.Power.Max.LastDay.TimeStamp (Read Only)
Description Displays the timestamp of maximum power value during the last day.
Legal Values String of up to 254 ASCII characters
Write Privilege Configure iDRAC
License Required iDRAC7 Express or iDRAC7 Enterprise
Dependency None
255