Reference Guide

cfgCurrentIPv6DNSServersFromDHCP6
Description Indicates whether the DNS server addresses are assigned
from the DHCPv6 server.
Legal Values
Default
cfgCurrentIPv6DNSServer1
Description Displays the IPv6 address for DNS server 1.
Legal Values
Default
cfgCurrentIPv6DNSServer2
Description Displays the IPv6 address for DNS server 2.
Legal Values None
Default None
Example
racadm getconfig -g cfgCurrentIPv6LanNetworking
# cfgCurrentIPv6Enabled=1
# cfgCurrentIPv6AutoConfigWasUsed=1
# cfgCurrentLinkLocalAddress=fe80::21e:4fff:fe1f:5371/64
# cfgCurrentIPv6Address1=2009:123::e48f:9dd8:6f51:a669/64
# cfgCurrentIPv6Address2=fd88:1::21e:4fff:fe1f:5371/64
# cfgCurrentIPv6Address3=fd88:2::21e:4fff:fe1f:5371/64
# cfgCurrentIPv6Gateway=fe80::21c:23ff:fe77:6215
# cfgCurrentIPv6DNSServersFromDHCP6=1
# cfgCurrentIPv6DNSServer1=2009:123::1
# cfgCurrentIPv6DNSServer2=::
cfgIPv6URL
This group specifies properties used to configure iDRAC IPv6 URL.
The following sections provide information about the objects in the cfgIPv6URL group.
cfgIPv6URLstring (Read Only)
Description The iDRAC IPv6 URL.
Legal Values A string of up to 80 characters.
Default <
blank
>
cfgIpmiSerial
This group specifies properties used to configure the IPMI serial interface of the BMC.
234