Reference Guide

cfgServerPowerSupply
This group is applicable only for iDRAC and contains information related to the power supplies. The following sections
provide information about the objects in the cfgServerPowerSupply group.
The cfgServerPowerSupply object group is applicable only for iDRAC on Rack and Tower Servers and not for iDRAC
Enterprise on Blade Servers.
NOTE: The getconfig subcommand always shows eight cfgServerPowerSupply indexes, even if two power supplies
are installed in the system or the system supports a maximum of two power supply units. For the uninstalled and
unsupported units, all the objects in the
cfgServerPowerSupply group displays a value of 0.
cfgServerPowerSupplyIndex
Description Specifies index of the power supply unit.
NOTE: Indexes from 1 – 8 are supported to support up
to 8 power supply units. If any power supply unit is
not present, cfgServerPowerSupplyOnlineStatus is
absent and for all the other properties, it is 0.
Legal Values Integer from 1 - 8
Default None
cfgServerPowerSupplyMaxInputPower (Read Only)
Description Displays the AC input rated power in Watts.
Legal Values A string of up to 32 characters.
Default 0
cfgServerPowerSupplyMaxOutputPower (Read Only)
Description Displays the AC output rated power in Watts.
Legal Values A string of up to 32 characters.
Default 0
cfgServerPowerSupplyOnlineStatus (Read Only)
Description Displays the status of the power supply unit.
Legal Values
0 - Present
1 - Absent
2 - Failure
3 - Predictive failure
Default 0