Users Guide
Severity Message Cause
Critical A PCI parity error was detected on a
component at slot <number>.
Parity error was detected on the PCI bus.
Critical A PCI system error was detected on a
component at bus <number> device <number>
function <number>.
PCI error detected by device.
Critical A PCI system error was detected on a
component at slot <number>.
PCI error detected by device.
Critical Persistent correctable memory error logging
disabled for a memory device at location
<location>.
Single bit error logging is disable when too many
SBE get logged for a memory device.
Critical All event logging is disabled.
Non-
Recoverable
CPU protocol error detected. The processor protocol entered a non-recoverable
state.
Non-
Recoverable
CPU bus parity error detected. The processor bus PERR entered a non-
recoverable state.
Non-
Recoverable
CPU initialization error detected. The processor initialization entered a non-
recoverable state.
Non-
Recoverable
CPU machine check detected. The processor machine check entered a non-
recoverable state.
Critical Memory redundancy is lost.
Critical A bus fatal error was detected on a
component at bus <number> device <number>
function <number>.
Fatal error is detected on the PCIe bus.
Critical A software NMI was detected on a component
at bus <number> device <number> function
<number>.
Chip error is detected.
Critical Failed to program virtual MAC address on a
component at bus <number> device <number>
function <number>.
Flex address could be programmed for this device.
Critical Device option ROM on mezzanine card
<number> failed to support Link Tuning or
FlexAddress.
Option ROM does not support Flex address or
linking tuning.
Critical Failed to get Link Tuning or FlexAddress data
from iDRAC.
NOTE: For information on other server related LCD messages, see "Server User Guide".
LCD Module and Server Status Information
The tables in this section describe status items that are displayed on the front panel LCD for each type of component in
the chassis.
225