Users Guide

Table 47. PSU Status Screens
Severity Message Cause
Critical Power supply <number> failed. The PSU has failed.
Critical The power input for power supply <number> is
lost.
Loss of AC power or AC cord unplugged.
Warning Power supply <number> is operating at 110 volts,
and could cause a circuit breaker fault.
Power supply is plug into a 110 volt source.
Table 48. Server Status Screen
Severity Message Cause
Warning The system board ambient temperature is less
than the lower warning threshold.
Server temperature is getting cool.
Critical The system board ambient temperature is less
than the lower critical threshold.
Server temperature is getting cold.
Warning The system board ambient temperature is
greater than the upper warning threshold.
Server temperature is getting warm.
Critical The system board ambient temperature is
greater than the upper critical threshold.
Server temperature is getting too hot.
Critical The system board Current Latch current is
outside of the allowable range
Current crossed a failing threshold.
Critical The system board battery failed. CMOS battery is not present or has no voltage.
Warning The storage battery is low. ROMB battery is low.
Critical The storage battery failed. CMOS battery is not present or has no voltage.
Critical The CPU <number> <voltage sensor name >
voltage is outside of the allowable range.
Critical The system board<voltage sensor name >
voltage is outside of the allowable range.
Critical The mezzanine card <number> <voltage
sensor name > voltage is outside of the
allowable range.
Critical The storage <voltage sensor name > voltage is
outside of the allowable range.
Critical CPU <number> has an internal error (IERR). CPU failure.
Critical CPU <number> has a thermal trip (over-
temperature) event.
CPU overheated.
Critica CPU <number> configuration is unsupported. Incorrect processor type or in wrong location.
Critical CPU <number> is absent. Required CPU is missing or not present.
223