Quick Reference Guide
If errors are not encountered, this subcommand displays
the contents of the specified configuration.
Example
• racadm getconfig -g
cfgLanNetworking
Displays all of the configuration properties
(objects) that are contained in the group
cfgLanNetworking.
• racadm getconfig -f myrac.cfg
Saves all group configuration objects from iDRAC
to myrac.cfg.
• racadm getconfig -h
Displays a list of the available configuration
groups on iDRAC in an alphabetical order.
• racadm getconfig -u root
Displays the configuration properties for the user
named root.
• racadm getconfig -g cfgUserAdmin
-i 2 -v
Displays the user group instance at index 2 with
verbose information for the property values.
getdcinfo
Description Displays general I/O module and daughter card configuration information. Only the
CMC controls daughtercards.
To use this subcommand, you must have CMC Login User privilege.
NOTE: Fabric verification for server DCs is performed only when the chassis is
powered on. When the chassis is on standby power, iDRACs on the server modules
remain powered off and thus are unable to report the server's DC fabric type. The
DC fabric type may not be reported in the CMC user interface until iDRAC on the
server is powered on.
Synopsis
racadm getdcinfo
Input -n — Displays the model names for the daughter cards in servers.
Example
The example output below is for a system with multi-slot servers.
racadm getdcinfo
Group A I/O Type : Gigabit Ethernet
Group B I/O Type : Gigabit Ethernet
Group C I/O Type : 10 GbE XAUI
<IO#> <Type> <State> <Role>
switch-1 Gigabit Ethernet OK Master
switch-2 None N/A N/A
42