Quick Reference Guide
fwupdate
Description Allows you to update the firmware on the iKVM, active CMC, standby CMC, server
iDRACs, or an IOM infrastructure device. You can:
• Check the firmware update process status.
• Update iDRAC or CMC firmware from a FTP or a TFTP server by providing an IP
address and optional path.
• Update iDRAC or CMC firmware from the local file system using Local and
Remote RACADM.
• Rollback to the standby firmware.
• This subcommand performs updates to the iDRAC firmware (if CMC firmware
version is 2.0 or later and iDRAC firmware version is 1.4) when the existing
firmware is corrupted. There can only be a single update operation in progress
at any time. In addition, the fwupdate subcommand may only update one or
more devices of a single kind at a time.
To use this subcommand for CMC you must have Chassis Configuration Administrator
privilege and for iDRAC you must have Configure iDRAC permission.
NOTE: Running the fwupdate subcommand to update the firmware on the active
CMC resets itself causing all network connections to be dropped. During update of
all other modules, including the standby CMC, the active CMC continues to run
normally without resetting.
NOTE: The fwupdate subcommand generates an error when used on the extension
slot of a multi-slot server.
Synopsis For iDRAC:
racadm fwupdate -s
racadm fwupdate -g -u -a <TFTP_Server_IP_Address>
[-d <
path>]
racadm -r <iDRAC7 IP_Address> -u <username> -p <password>
fwupdate -f <
ftpserver ip> <ftpserver username>
<ftpserver password> -d <path> where path is the location
on the ftp server where firming.d7 is stored.
racadm fwupdate -r
racadm fwupdate -p -u [-d <path>]
For CMC:
For local RACADM:
racadm fwupdate -g -u -a <tftp server ip address or
FQDN
> -d <path> [-m <module>]
racadm fwupdate -f <ftp server ip address or FQDN>
<username> <password> -d <path> [-m
<module>]
racadm fwupdate -u -m iominf-<n>
racadm fwupdate -s [-m <module>]
racadm fwupdate -c [-m <module>]
36