Quick Reference Guide

cfgIpmiPetIPv6Index (Read Only)
Description Unique identifier for the index corresponding to the trap.
Legal Values 1 – 4
Default <
index value
>
cfgIpmiPetIPv6AlertDestIpAddr
Description Configures the IPv6 alert destination IP address for the
trap.
Legal Values IPv6 address
Default <
blank
>
cfgIpmiPetIPv6AlertEnable (Read/Write)
Description Enables or disables the IPv6 alert destination for the trap.
Legal Values
1 (TRUE)
0 (FALSE)
Default 0
cfgIpmiPef
This group is applicable only for iDRAC and is used to configure the platform event filters available on the managed
server.
The event filters can be used to control policy related to actions that are triggered when critical events occur on the
managed server.
The following sections provide information about the objects in the cfgIpmiPef group.
cfgIpmiPefName (Read Only)
Description Specifies the name of the platform event filter.
Legal Values A string of up to 255 characters.
Default The name of the index filter.
cfgIpmiPefIndex (Read/Write)
Description
Specifies the index of a specific platform event filter.
Legal Values
For iDRAC on Rack and Tower Servers: 1 – 22
For iDRAC Enterprise on Blade Servers: 1 - 9
174