Quick Reference Guide

cfgChassisPerformanceOverRedundancy (Read/Write)
Description Enables or disables server performance over power
redundancy. When enabled, this option favors server
performance and server powerup, over maintaining power
redundancy. When disabled, the system favors power
redundancy over server performance. When disabled,
then if the power supplies in the chassis do not provide
sufficient power, both for redundancy, as well as full
performance, then some servers may not be granted
sufficient power for full performance, or may not be
powered on, in order to maintain redundancy.
Legal Values
0 (disabled)
1 (enabled)
Default 1 (enabled)
cfgChassisInMaxPowerCapacity (Read Only)
Description Indicates the total chassis power budget (in watts) available for chassis operation.
Legal Values None
Default None
cfgChassisInRedundancyReserve (Read Only)
Description Indicates the amount of redundant power (in watts) in reserve that can be utilized in
the event of an AC grid or PSU failure. This value is 0 if the Redundancy Policy is set to
0 (no redundancy).
Legal Values 0 (disabled)
1 (enabled)
Default None
cfgChassisInPowerServerAllocation (Read Only)
Description Indicates (in watts) the cumulative power allocated to servers. There is no default as
this parameter is very specific to the particular customer configuration.
Legal Values None
Default None
cfgChassisInfrastructureInPowerAllocation (Read Only)
Description
Indicates the estimated cumulative DC output power consumption (in watts),
determined from a field replaceable unit (FRU) on the hardware modules in the chassis.
Legal Values None
169