Quick Reference Guide

cfgChassisRedundancyPolicy (Read/Write)
Description Sets the redundancy policy of the chassis.
Legal Values
0 (no redundancy)
1 (AC redundancy)
2 (power supply redundancy)
Default 0 (no redundancy)
cfgChassisDynamicPSUEngagementEnable (Read/Write)
Description Enables or disables dynamic engagement.
Legal Values
0 (disabled)
1 (enabled)
Default 0 (disabled)
cfgChassisAllow110VACOperation (Read/Write)
Description Enables or disables normal chassis power allocations
when any power supply unit is connected to 110V AC
service. If disabled and 110V power supplies are detected,
all subsequent server power allocation requests are
denied. In this mode additional servers cannot be
powered on, regardless of server priority.
Legal Values
0 (disabled)
1 (enabled)
Default 0 (disabled)
cfgChassisMaxPowerConservationMode (Read/Write)
Description Enables or disables maximum power conservation mode. When enabled, all servers
are immediately reduced to their minimum power levels, and all subsequent server
power allocation requests are denied. In this mode, performance of powered on
servers may be degraded, and additional servers cannot be powered on, regardless
of server priority.
Legal Values
0 (disabled)
1 (enabled)
Default 0 (disabled)
168