cfgSDWriteProtect (Read Only)
Description Displays if the physical write protect latch on the SD card
is enabled or disabled.
NOTE: This command is deprecated from iDRAC 1.5
and CMC 3.0 releases onwards. The functionality of
this command is now covered by
cfgVFlashSDWriteProtect. While execution of
the cfgSDWriteProtect command is successful,
it is recommended to use the
cfgVFlashSDWriteProtect command. For
more information, see "cfgVFlashSDWriteProtect" on
page 132.
Legal Values
• 1 (TRUE)
• 0 (FALSE)
Default 0
cfgServerInfo
For iDRAC this group allows you to select the BIOS first boot device and provides the option to boot the selected device
only once.
For CMC, this group allows you to displays information for and configure a server in the chassis.
Use this object with the config or getconfig subcommands.
To use this object property for CMC, you must have Chassis Configuration Administrator privilege.
NOTE: For CMC, you can configure any setting that is not preceded by the hash sign (#) in the output. To modify a
configurable object, use the -o option
The following sections provide information about the objects in the cfgServerInfo group.
cfgServerInfoIndex (Read Only)
Description Displays the index name of the server.
This object is applicable only to CMC.
Legal Values None
Default None
cfgServerSlotNumber (Read Only)
Description
Specifies the location of the specified server (1–16) in the
chassis.
This object is applicable only to CMC.
Legal Values None