Owner's Manual

Diagnostics 473
Critical The system board fail-safe voltage
is outside of the allowable range.
This event is generated when the
system board voltages are not at
normal levels.
Critical The watchdog timer expired. The iDRAC watchdog timer
expires and no action is set.
Critical The watchdog timer reset the
system.
The iDRAC watchdog detected
that the system has crashed (timer
expired because no response was
received from Host) and the action
is set to reboot.
Critical The watchdog timer powered off
the system.
The iDRAC watchdog detected
that the system has crashed (timer
expired because no response was
received from Host) and the action
is set to power off.
Critical The watchdog timer power cycled
the system.
The iDRAC watchdog detected
that the system has crashed (timer
expired because no response was
received from Host) and the action
is set to power cycle.
Critical Log is full. The SEL device detects that only
one entry can be added to the SEL
before it is full.
Warning Persistent correctable memory
errors detected on a memory
device at location <location>.
Warning Persistent correctable memory
error rate has increased for a
memory device at location
<location>.
Correctable ECC errors reach a
critical rate.
Critical Multi-bit memory errors detected
on a memory device at location
<location>.
An uncorrectable ECC error was
detected.
Table 13-9. Server Status Screen
(continued)
Severity Message Cause