Owner's Manual

Power Management 333
To disable Server Performance Over Power Redundancy, perform the
following steps:
1
Click
Chassis Overview
in the system tree.
2
Click
Power
Configuration
.
3
Clear Server
Performance Over Power Redundancy
and click
Apply
.
Using RACADM
To enable Server Performance Over Power Redundancy, perform the following
steps:
1
Open a serial/Telnet/SSH text console to CMC and log in.
2
Enable Server Performance Over Power Redundancy:
racadm config -g cfgChassisPower -o
cfgChassisPerformanceOverRedundancy 1
To disable Server Performance Over Power Redundancy, perform the
following steps:
1
Open a serial/Telnet/SSH text console to CMC and log in.
2
Disable Server Performance Over Power Redundancy:
racadm config -g cfgChassisPower -o
cfgChassisPerformanceOverRedundancy 0
Remote Logging
Power consumption can be reported to a remote syslog server. Total chassis
power consumption, minimum, maximum, and average power consumption
over a collection period can be logged. For more information on enabling this
feature and configuring the collection/logging interval, see related sections
below.