Owner's Manual
Using the CMC Web Interface 243
Table 5-64. Remote File Sharing Settings
Setting Description
Image File Path Image File Path is only needed for connect and deploy operations. It
does not apply to disconnect operations. The path name of the
network drive is mounted to the server through a Windows SMB or
Linux/Unix NFS protocol.
For example, to connect to CIFS:
//
<IP to connect for CIFS file
system>/<file path>/<image name>
To connect to NFS:
//
<IP to connect for NFS file
system>:/<file path>/<image name>
File names that end with .img are connected as virtual floppies. File
names that end with .iso are connected as virtual CD/DVDs. The
maximum number of characters is 511.
User Name User Name is only needed for connect and deploy operations.
It does not apply to disconnect operations. The maximum number
of characters you can specify in this field is 40.
Password Password is only needed for connect and deploy operations. It does
not apply to disconnect operations. The maximum number of
characters you can specify in this field is 40.
Slot Identifies the location of the slot. Slot numbers are sequential from
1 to 16 (for the 16 available slots in the chassis).
Name Displays the name of the slot. Slots are named depending on their
position in the chassis.
Model Displays the model name of the server.
Power State Displays the power status of the server:
N/A – CMC has not yet determined the power state of the server.
Off – Either the server is off or the chassis is off.
On – Both the chassis and the server are on.
Powering On – Temporary state between Off and On. On success,
the Power State is On.
Powering Off – Temporary state between On and Off. On success,
the Power State is Off.