Owner's Manual
240 Using the CMC Web Interface
5
For additional information, click
Help
.
Configuring FlexAddress
If you purchase FlexAddress with your chassis, is installed and active when
you power up your system. If you purchase FlexAddress separately, you must
install the SD feature card using the instructions in the Chassis Management
Controller (CMC) Secure Digital (SD) Card Technical Specification document
at support.dell.com/manuals.
The server must be off before you begin configuration. You can enable or
disable FlexAddress on a per fabric basis. Additionally, you can enable/disable
the feature on a per slot basis. After you enable the feature on a per-fabric
basis, you can then select slots to be enabled. For example, if Fabric-A is
enabled, any slots that are enabled have FlexAddress enabled only on Fabric-
A. All other fabrics use the factory-assigned WWN/MAC on the server.
Selected slots have FlexAddress enabled for all fabrics that are enabled.
For example, it is not possible to enable Fabric-A and B, and have Slot 1 be
FlexAddress enabled on Fabric-A but not on Fabric-B.
NOTE: You can also configure FlexAddress using the command line interface.
For more command information, see "Using FlexAddress" on page 249.
NOTE: Make sure that the Blade Servers are powered off before changing the
fabric level (A, B, C, or DRAC) flex address.
BIOS Version Displays the current BIOS version of the server module.
Slot Slot number of the server associated with the fabric location.
Location Displays the location of the Input/Output (I/O) module in the
chassis by group number (A, B, or C) and slot number (1 or 2).
Slot names: A1, A2, B1, B2, C1, or C2.
Fabric Displays the type of fabric.
Server-Assigned Displays the server-assigned WWN/MAC addresses that are
embedded in the controller's hardware.
Chassis-Assigned Displays the chassis-assigned WWN/MAC addresses that are
used for the particular slot.
Table 5-63. Status Page Information
(continued)