Quick Reference Guide

To use this subcommand, you must have Administrator privilege.
Synopsis
racadm setassettag -m chassis <asset tag>
Input -m <
module
> — Specifies the module whose asset tag you want to set.
Legal value: chassis
You can obtain the same output if you do not include this option, as there is only one legal
value.
<
assettag
> is a maximum of 64 non-extended ASCII characters.
Example
racadm setassettag -m chassis 783839–33
racadm setassettag 783839–33
The asset tag was changed successfully.
setchassisname
Description Sets the name of the chassis in the LCD.
To use this subcommand, you must have Administrator
privilege.
Synopsis
racadm setchassisname <name>
NOTE: Chassisname is a maximum of 64 non-extended
ASCII characters.
Example
racadm setchassisname dellchassis-1
The chassis name was set successfully.
setflexaddr
Description Enables/disables FlexAddress on a particular slot/fabric.
To use this subcommand, you must have Chassis Configuration Administrator privilege.
If the fabric type is determined to be Infiniband, the operation is canceled and the
command returns an error. If the FlexAddress feature is not activated, the command
returns an error.
NOTE: The server must be powered off to change the slot state. All servers must be
powered off to change the fabric state. The MAC/WWN addresses must be managed
locally (not by an external console) to use this command.
Synopsis
racadm setflexaddr [-i <slot#> <state>]
[-f <fabricName> <state>]
<
slot#
> = 1 to 16
<
fabricName
> = A, B, C
<
state
> = 0 or 1
where 0 is disable and 1 is enable.
Input
-i <
slot#
> <
state
> — Enables/disables FlexAddress for the specified slot.
-f <
fabricName
> <
state
> — Enables/disables FlexAddress for the specified fabric.
89