Quick Reference Guide

To use this subcommand, you must have Execute Server
Control Commands permission.
Synopsis
racadm serveraction <action>
Input
-m <
module
> - server-n : where n = 1 to 16
-a - Performs action on all servers. Not allowed
with the powerstatus action.
-f - Force the action. Required for the reseat
action.
<
action
>- Specifies the action. The options for the
<
action
> string are:
— graceshutdown — Performs a graceful
shutdown of the server. If the operating system on
the server cannot be shutdown cleanly, then this
operation will not be performed.
— hardreset — Performs a reset (reboot)
operation on the managed system.
— powercycle — Issues a power-cycle operation
on the managed system. This action is similar to
pressing the power button on the system’s front
panel to power down and then power up the
system.
— powerdown — Powers down the managed
system.
— powerup — Powers up the managed system.
— powerstatus — Displays the current power
status of the server (ON or OFF).
— reseat — Performs virtual reseat of the server.
This operation simulates reseating the blade by
resetting the iDRAC on that blade.
NOTE: The action powerstatus is not allowed with -a
option.
Output Displays an error message if the requested operation fails,
or a success message if the operation is completed.
Example
Power Down Blade 16 from the CMC
racadm serveraction -m server-16 powerdown
Server power operation successful
Power Down Blade from iDRAC
racadm serveraction powerdown
Server power operation successful
Power Down Blade 16 from CMC when Power is
already Off on that blade
racadm serveraction -m server-16 powerdown
Server is already powered OFF.
Power Down Blade from iDRAC when Power is
already off on that blade.
racadm serveraction powerdown
Server is already powered OFF
Get Power Status of blade 16 on CMC
87