Quick Reference Guide

Example
racadm iping6 10.9.72.254
IPING6 10.9.72.254 (10.9.72.254): 56
data bytes
64 bytes from 10.9.72.254: icmp_seq=0
ttl=121 time=2.9
ms
--- 10.9.72.254 ping statistics ---
1 packets transmitted, 1 packets
received, 0 percent
packet loss
round-trip min/avg/max = 2.9/2.9/2.9 ms
racdump
Description Provides a single command to get dump, status, and
general iDRAC board information.
For CMC, this subcommand displays the comprehensive
chassis status and configuration state information, as well
as historic event logs. Used for post deployment
configuration verification and during debugging sessions.
To use this subcommand for CMC you must have
Administrator privilege and for iDRAC you must have
Debug permission.
Synopsis
racadm racdump
Input Racdump includes the following subsystems and
aggregates the following RACADM commands:
General System/RAC information - getsysinfo
Session information - getssinfo
Sensor information - getsensorinfo
Switches information (IO Module) - getioinfo
Mezzanine card information (Daughter card) -
getdcinfo
All modules information - getmodinfo
Power budget information - getpbinfo
KVM information - getkvminfo
NIC information (CMC module) - getniccfg
Redundancy information - getredundancymode
Trace log information - gettracelog
RAC event log - getraclog
System event log - getsel
Output The following information is displayed when the racdump
subcommand is processed:
General system/RAC information
Coredump
Session information
80