Quick Reference Guide
To use this subcommand, you must have Login to iDRAC permission.
Synopsis
racadm getsvctag
Input
getsvctag
Output
Y76TP0G
Example
racadm getsvctag
getsysinfo
Description Displays information related to iDRAC, managed system, and watchdog
configuration.
To use this subcommand, you must have Login to iDRAC permission.
NOTE: The local racadm getsysinfo subcommand on Linux displays the
PrefixLength on separate lines for IPv6 Address 2 – IPv6 Address 15 and the Link
Local Address.
NOTE: The Hostname and OS Name fields in the getsysinfo output display
accurate information only if Dell OpenManage Server Administrator is installed
on the managed system. Else, these fields may be blank or inaccurate. An
exception to this are VMware operating system names, which are displayed
even if Server Administrator is not installed on the managed system.
Synopsis
racadm getsysinfo [-d] [-s] [-w] [-A] [-c] [-4]
[-6]
Input
• -4 - Displays IPv4 settings
• -6 - Displays IPv6 settings
• -c - Displays common settings
• -d - Displays iDRAC information
• -s - Displays system information
• -w - Displays watchdog information
• -A - Eliminates the printing of headers/labels
NOTE: If the -w option is not specified, then the other options are used as
defaults.
Output
RAC Information:
RAC Date/Time = 10/27/2009 14:38:00
Firmware Version = 1.30
Firmware Build = 20
Last Firmware Update = 10/26/2009 16:55:08
Hardware Version = 0.01
MAC Address = 00:24:e8:2e:c5:d3
Common settings:
Register DNS RAC Name = 1
DNS RAC Name = eval710-08-r
66