cfgNetTuningNic100MB (Read/Write)
Description Specifies the speed to use for the RAC NIC. This property
is not used if cfgNetTuningNicAutoNeg is set to 0
(disabled).
Legal Values
• 0 (10 MBit)
• 1 (100 MBit)
• 2 (1000 MBit)
Default 1
cfgNetTuningNicFullDuplex (Read/Write)
Description Specifies the duplex setting for the RAC or CMC NIC. This
property is used only if the cfgNetTuningNicAutoNeg is
set to 0 (disabled).
Legal Values
• 0 (Half Duplex)
• 1 (Full Duplex)
Default 1
cfgNetTuningNicMtu (Read/Write)
Description The size in bytes of the maximum transmission unit used
by iDRAC or CMC NIC.
Legal Values 576 – 1500
Default 1500
NOTE: IPv6 requires a minimum MTU of 1280. If IPv6 is enabled, and cfgNetTuningMtu is set to a lower value, the
CMC uses an MTU of 1280.
cfgSensorRedundancy
This group is used to set the power supply redundancy. This group is applicable only for iDRAC.
The following sections provide information about the objects in the cfgSensorRedundancy group.
This group is applicable only for iDRAC on Rack and Tower Servers and not for iDRAC Enterprise on Blade Servers.
cfgSensorRedundancyIndex (Read Only)
Description
Specifies index for the sensor redundancy group being
read. Only power supply redundancy is supported.
Legal Values 1
Default None