Quick Reference Guide

Example
racadm getconfig -g cfgStandardSc
hema
# cfgSSADRoleGroupIndex=1
cfgSSADRoleGroupName=blsys-1
cfgSSADRoleGroupDomain=
cfgSSADRolGroupPrivilege=3081
The following table displays the bit masks for Role Group privileges:
Role Group Privilege Bit Mask
Login to iDRAC 0x00000001
Configure iDRAC 0x00000002
Configure Users 0x00000004
Clear Logs 0x00000008
Execute Server Control Commands 0x00000010
Access Virtual Console 0x00000020
Access Virtual Media 0x00000040
Test Alerts 0x00000080
Execute Debug Commands 0x00000100
cfgChassisPower
This group is applicable only to CMC and contains parameters to display or configure power for the chassis.
Use this object with the config or getconfig subcommands.
To use this object property, you must have Chassis Configuration Administrator privilege.
NOTE: You can configure any setting that is not preceded by the hash sign (#) in the output. To modify a
configurable object, use the -o option.
The following sections provide information about the objects in the cfgChassisPower group.
cfgChassisExternalPowerManagementMode
Description Allows to enable or disable External Power Management.
When this mode is enabled:
The chassis power capacity is set to maximum
value.
The server power priorities are set to 1.
These properties cannot be changed by racadm
or GUI.
When the external power management mode is disabled,
the power capacity and server power priorities are
preserved.
Legal Values
Default
163