Owner's Manual
88 Using the RACADM Command Line Interface
Setting up the CMC VLAN (IPv4 and IPv6)
1
Enable the VLAN capabilities of the external chassis management
network:
racadm config -g cfgLanNetworking -o
cfgNicVLanEnable 1
2
Specify the VLAN ID for the external chassis management network:
racadm config -g cfgLanNetworking -o cfgNicVlanID
<VLAN id>
The valid values for <
VLAN id
> are 1– 4000 and 4021– 4094. Default is 1.
For example:
racadm config -g cfgLanNetworking -o cfgNicVlanID
1
3
Then, specify the VLAN priority for the external chassis management
network:
racadm config -g cfgLanNetworking -o
cfgNicVLanPriority <VLAN priority>
The valid values for <
VLAN priority
> are 0–7. Default is 0.
For example:
racadm config -g cfgLanNetworking -o
cfgNicVLanPriority 7
You can also specify both the VLAN ID and the VLAN priority with a
single command:
racadm setniccfg -v <VLAN id> <VLAN priority>
For example:
racadm setniccfg -v 1 7