Owner's Manual
Diagnostics 473
NOTE: For information on other server related LCD messages, see "Server User
Guide".
LCD Module and Server Status Information
The tables in this section describe status items that are displayed on the front
panel LCD for each type of component in the chassis.
Critical Memory redundancy is lost.
Critical A bus fatal error was detected on a
component at bus <number>
device <number> function
<number>.
Fatal error is detected on the PCIe
bus.
Critical A software NMI was detected on a
component at bus <number>
device <number> function
<number>.
Chip error is detected.
Critical Failed to program virtual MAC
address on a component at bus
<number> device <number>
function <number>.
Flex address could be programmed
for this device.
Critical Device option ROM on mezzanine
card <number> failed to support
Link Tuning or FlexAddress.
Option ROM does not support
Flex address or linking tuning.
Critical Failed to get Link Tuning or
FlexAddress data from iDRAC.
Table 13-10. CMC Status
Item Description
Example: CMC1,
CMC2
Name/Location.
No Errors If no error occurs then “No Errors” is displayed, else lists error
messages.
Table 13-9. Server Status Screen
(continued)
Severity Message Cause