Table 13-4. Enclosure/Chassis Status Screen
Severity Message Cause
Critical Fan <number> is removed. This fan is required for proper
cooling of the enclosure/chassis.
Warning Power supply redundancy is
degraded.
One or more PSU have failed or
removed and the system can no
longer support full PSU
redundancy.
Critical Power supply redundancy is lost. One or more PSU have failed or
removed and the system is no
longer redundant.
Critical The power supplies are not
redundant. Insufficient resources
to maintain normal operations.
One or more PSU have failed or
removed and the system lacks
sufficient power to maintain
normal operations. This could
cause servers to power down.
Warning The control panel ambient
temperature is greater than the
upper warning threshold.
Chassis/Enclosure intake
temperature exceeded the warning
threshold.
Critical The control panel ambient
temperature is greater than the
upper warning threshold.
Chassis/Enclosure intake
temperature exceeded the warning
threshold.
Critical CMC redundancy is lost. CMC no longer redundant. This
happens if the standby CMC is
removed.
Critical All event logging is disabled. The Chassis/Enclosure cannot
store events to the logs. This
usually indicates a problem with
the control panel or control panel
cable.
Warning Log is full. Chassis has detected that only one
more entry can be added to the
CEL (hardware log) before it is
full.
Warning Log is almost full. Chassis event log is 75% full.