Owner's Manual

442 Troubleshooting and Recovery
Health OK The server is present and communicating with
CMC. In the event of a communication failure
between CMC and the server, the CMC
cannot obtain or display health status for the
server.
Informational Displays information about the server when
there is no change in health status (OK,
Warning, Se vere).
Warning Warning alerts have been issued, and
corrective action must be taken. If corrective
actions are not taken, critical or severe failures
that can affect the integrity of the server can
occur.
Severe At least one failure alert has been issued.
Severe status represents a CMC system failure,
and corrective action must be taken
immediately.
iDRAC Status Displays the status of the server iDRAC embedded
management controller:
N/A
- Server is not present, or the chassis is not powered on.
Ready
- iDRAC is ready and operating normally.
Corrupted
- iDRAC firmware is corrupted. Use the iDRAC
firmware update utility to repair the firmware.
Failed
- Unable to communicate with iDRAC. Use the Virtual
Reseat check box to clear the error. If this fails, manually
remove and replace the server to clear the error.
FW Update
- iDRAC firmware update in progress; allow the
update to complete before attempting any action.
Initializing
- iDRAC reset in progress; wait for the controller to
complete powering-on before attempting any action.
Table 12-13. Virtual Reseat Server
(continued)
Attribute Description